Gambar PRO631120-L-384 120KVA

UPS PROLINK Giant Industrial (3P/1P) – Tower

Prolink Giant Industrial Series are single-phase and three-phase output UPS systems which
apply a true online double-conversion technology. Double conversion between input/output,
battery and bypass are totally isolated power line noise, spike and transients, keeping power
failure away from critical loads. It is designed to deliver clean and high-quality electrical
power for electrical loads. All Giant Industrial Series UPS systems accept dual-mains inputs.

– TRUE ONLINE DOUBLE CONVERSION WITH DSP CONTROL
– ROBUST ELECTRICAL PERFORMANCE TO PREVENT DAMAGE FROM TOP AND BOTTOM CONNECTIONS
– SCREWLESS CABINET DESIGN AND FULLY COATING PCBAS TO WITHSTAND HARSH ENVIRONMENT
– UNIQUE VENTILATION DESIGN FOR EFFECTIVE HEAT DISSIPATION
– FLEXIBLE BATTERY CONFIGURATION ADAPTS DIFFERENT APPLICATIONS
– ACCEPTS DUAL-MAINS INPUTS

Key Features PRO631120-L-384 120KVA

• Robust electrical performance
This UPS is designed to accept wide input voltage and frequency range to
cope with the worst utility conditions. It can eliminate harmful distortion
from utility power and withstand all kinds of severe impacts from various
loads. It’s capable to support heavy duty equipment, production equipment and DCS (Distributed Control System) system.

• Screwless cabinet design and fully coating PCBAs to withstand harsh environment
The outside cabinet is designed only with locks without any screws and all
PCBAs are coated for anti-moisture, anti-electric leakage, anti-dust and
anti-corrosion. Its robust design is suitable for harsh environment with
high temperature, high humidity, dense dust, salt, or fierce vibration.

• Front access makes maintenance and replacement easy
It’s considerate to allow easy access to all of the electronic
cards and power componentsin the unit through the front
panel for further maintenance and replacement.

• High short-circuit and overload
This UPS is built-in high short-circuit protection. Once short circuit occurs,
this mechanism will be activated. The load will stay protected and the UPS
will remain intact. High overload protection supports 100~110% load
continuously for 60 minutes and 110~150% load for up to 10 minutes.

• Monitoring features
Users can easily monitor and access to their UPS status from a comprehensive LCD display. Potential free dry contacts are provided for UPS alarm
monitoring via hard wire. The UPS systems have USB and RS-485 communication ports as standard, with a built-in intelligent slot for additional
adapters, protocol converters and relay contact cards. SNMP option is also
available for power management via SNMP manager and web browser.

• Adjustable battery number design
The number of connected batteries can be adjusted flexibly
based on different power demands. External standalone
type battery banks can be connected for longer backup
requirements.

• Unique ventilation design for effective heat dissipation
Unique ventilation design allows heat to rise by the process
of convection. Therefore, the UPS cabinets can be added in
parallel side by side for space-saving.

• Parallel capability
Up to 4 units in parallel can be operated to increase system
capacity as well as operation reliability for power redundancy

• Isolation Transformer at the output
Galvanic isolation transformer is provided for electrical
isolation between UPS output and load. It is also used to
protect against electric shock, to suppress electrical noise in
sensitive devices.

• Available capacity range
– Giant Industrial series (220VDC) (3P/1P) series is
available in models ranging from 10kVA to 120kVA.
– Giant Industrial series (384VDC) (3P/1P) series is
available in models ranging from 10kVA to 120kVA.
– Giant Industrial series (384VDC) (3P/3P) series is
available in models ranging from 10kVA to 400kVA.

SPECIFICATIONS PRO631120-L-384 120KVA

GENERAL
– UPS Type : Tower
– Phase : 3 phase in / 1 phase out
– Rating (VA) : 120K
– Nominal Power (W) : 96K
– Dimension (mm) : 800 x 800 x 1800 (D x W x H)
– Weight (kg) : 920

INPUT
– Connection Type : Terminal
– Nominal Voltage : 3 x 380VAC / 400VAC / 415VAC (3Ph or 3Ph + N)
– Acceptable Voltage Range : 304VAC ~ 456VAC
– Frequency : 50/60Hz ± 10%

OUTPUT
– Connection Type : Terminal
– Nominal Voltage : 220VAC/230VAC/240VAC (Selectable)
– Frequency : 50/60 Hz
– Frequency Synchronization Speed : 1~2 Hz/s
– Crest Factor : 3:1
– Harmonic Distortion : <2% (Linear Load) <4% (Non-linear Load)

BYPASS
– Connection Type : Hardwire 3-wire (1Ph+N+G)
– Input Voltage Range : 220VAC ± 25%
– Overload Capability : 1.5 In~1.8 In 1h~30s
– Short-circuit Capability : 1.8 In ~ >2.0 In 30s ~ 200ms

BATTERY
– Rectifier Type : 6 pulse
– Rated output voltage : 384 VDC
– Charger voltage : 290VDC ~ 435VDC (Adjustable)
– Charging Current (max) : 40A
– Battery Type : Support VRLA Battery
– Numbers : 32 Pcs (29 ~ 32 pcs adjustable)
– Reverse Diode : Yes
– Cold Start : Yes

×