Keor T Evo on-line double conversion UPS

Three phase VFI SS 111 – 20 kW – backup time 7 min CAT. N° 3 102 77

Gambar UPS Legrand Keor T Evo on-line double conversion - 3 102 77

PRODUCT DESCRIPTION

Product characteristics
UPS
– Nominal power: : 20 kW
– Backup time: : 7 min
– Dimensions (H x W x D): : 1020 x 265 x 800 mm
– Net weight: : 185 kg

General characteristics

KEOR T EVO – On-line double conversion UPS (tower) – three phase VFI SS 111
– For civil, commercial, industrial automation and IT applications requiring small three phase power (up to 20 kVA) with standard back up time in compact footprint
– Installation: downstream power generators. 3 level IGBT inverter
– DSP advanced control logic
– Power factor: 1 (kVA = kW). Efficiency up to 95%
– Internal Batteries
– Touch Screen Display
– Parallel connection possible: up to 4 UPSs. Dedicated input bypass line. Embedded manual bypass
– Full connectivity with RS232, RS485 (ModBus), 4xDry contacts, Net Interface Slot (SNMP), EPO, Generator Friendly port
– Equipped with wheels for easy moving of the UPS

 

specifications UPS Legrand CAT. N° 3 102 77

General specifications
– UPS Topology : On line double conversion VFI SS 111
– Architecture of the UPS : Stand alone, transformerless, On-Site Paralleling
– In/Out phase Configuration : Three phase-Three phase
– Neutral : Neutral Passing through
– Switching Technology : 3-Level IGBT
– Backfeed Protection : Internal, standard
– Output wave form on mains operation : Sinusoidal
– Output wave form on battery operation : Sinusoidal
– Standards : EN 62040-1, EN 62040-2, EN 62040-3

Input
– Nominal Voltage : 400 3ph+N+PE
– Voltage Range : 358 – 459 Ph-Ph full load, 208 – 459 Ph-Ph half load”
– Frequency : 45 – 65Hz
– THDin : < 5% at full load
– Power Factor : > 0.99

Bypass
– Nominal Voltage : 400 3ph+N+PE
– Voltage Range : 380/400/415V -18% +15% (adjustable)
– Frequency : 47-53Hz or 57-63Hz (adjustable)
– Bypass Type : Static and Electro-mechanic
– Transfer Time : Zero
– Manual Bypass : Built-in

 

Output with mains (AC-AC)
– Nominal Voltage : 380, 400, 415 3ph+N+PE
– Nominal Power : 20.000 VA
– Active Power : 20.000 W
– Voltage variation (static) : ± 1%
– THDv on nominal power (linear load) : < 2%
– THDv on nominal power (non-linear load) : < 4%
– Frequency : 50 Hz or 60 Hz (selectable)
– Frequency tolerance : ± 0,1% Synchronized with input frequency
– Current Crest Factor : 2.5:1 accordingly to IEC 62040-3
– Overload capability: 10 min 125% load with no bypass, 60 sec 150% load with no bypass

Output on battery (DC-AC)
– Nominal Voltage : 380, 400, 415 3ph+N+PE
– Nominal Power : 20.000 VA
– Active Power : 20.000 W
– Voltage variation (static) : ± 1%
– THDv on nominal power (linear load) < : 2%
– THDv on nominal power (non-linear load) : < 4%
– Frequency : 50 Hz or 60 Hz (selectable)
– Frequency tolerance : ± 0,01% free run
– Current Crest Factor : 2.5:1 accordingly to IEC 62040-3
– Overload capability : 10 min 125%, 60 sec 150%

Battery
– Type : Lead Acid, sealed, free maintenance VRLA
– Unit Capacity : 7 or 9 Ah (12V)
– Nominal UPS Battery Voltage ±: 216 Vdc (max ±216 Vdc)
– Nominal n. of possible internal battery : 36pcs (18×2)
– Max. n. of possible internal battery : 36pcs (18×2)
– Battery charger type : IGBT Rectifier also charges batteries
– Charging Cycle : Intelligent with boost charge and advanced management”
– Max Charging Current without derating : 2 A

Environmental specs
– Noise level @ 1m (50% load) : < 51dBA
– Operating temperature range : from 0°C to +40°C
– Stock temperature range : from -20°C to +50°C
– Humidity range : 20-95% not condensing
– Protection degree : IP20

Mechanical and miscellaneous
– Net Weight without batteries ¹ : 84 kg
– Dimensions (HxW xD) : 1020 x 265 x 800 mm
– Colour : Enclosure: RAL 7016Front Door Metal: RAL 9005
– Communication Interface : 1 serial port RS232, 1 RS485, 1 smart port for internal SNMP, 4 Dry Contacts, 1 EPO, 1 GENSET
– Input/Output connections : 3Ph + N + PE

×

PT. Platindo Karya Prima

× Contact Us