Galaxy VM 160 kVA UPS Single 400-400 V with Backfeed protection, Start up 5×8 – GVMSB160KHS
Galaxy VM 160 kVA UPS Single 400-400 V with Backfeed protection, Start up 5×8
Highly compact, energy efficient 3-phase UPS for data center, facility and industrial applications. to be used with external battery cabinets. Please click here for additional runtime information.
Includes: Built-in modbus protocol adapter , Dust filter , Installation guide , Integrated network management , Seismic compliance , Top and bottom cable entry
GVMSB160KHS Features
Galaxy VM 160 kVA UPS Single 400-400 V with Backfeed protection, Start up 5×8
Dry Contact inputs
User assignable inputs allow other equipment alarms to be monitored through the power system controller
Dry contact output
Provides remote notification of failures when used with APC environmental monitoring unit or system.
ECOnversion mode
Operating mode that ensures ultra high efficiency while charging the batteries, conditioning the load power factor and ensuring a Class 1 output voltage regulation.
Integrated network management
Provides complete remote monitoring and control of the UPS. Enables you to monitor remote UPS’s from a web browser or industry standard Network Management System.
Internal backfeed protection
Increase system defense from power anomolies.
Modbus RS-485 and Modbus TCP support
Enables remote monitoring and interfaces with StruxureWare™ Data Center Expert, building management systems, or other third-party systems.
Pre-installed dust filters
Protects the UPS from harsh environments
Top and bottom cable entry (standard)
Flexibility that allows the customer to decide – and at no extra cost.
Galaxy VM Features & Benefits
Availability
Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
Life Cycle monitoring
Allows predictive maintenance notification to ensure continuity on the entire UPS system.
Hot swappable fan replacement
Allows replacement of individual fans without going to bypass increasing availability and load protection.
Modular battery offer
Allows replacement of batteries without the need to go to maintenence bypass while maintaining availability and continuous protection of the load
Energy storage flexibility
Conventional flooded and modular battery offer along with different charging modes allows tailoring to specific back-up requirements.
Advanced electrical features
Excellent power conditioning, very low harmonic distortion through IGBT rectifier, input power factor correction, and high power efficiency
Parallel-capacity capable
Increases total power capacity by using multiple uninterruptible power supplies simultaneously.
Parallel-redundant capable
Power the connected equipment with multiple uninterruptible power supplies to increase system redundancy
Adaptability
Flexible Design
Available in a wide range of configurations to suit any operating environment
Serviceability
Low Mean Time To Repair (MTTR)
Front-access battery design places all of the connection points in easy reach to speed battery replacement.
Technical support
Our experienced technical support engineers are available to answer your questions, giving you peace of mind knowing the help you need is there when you need it.
Multiple levels of service
With the option of packages or individual service components, our services are structured to allow you to pick and choose what you would like APC to do for you.
Front-access servicing
Simplifies installation and UPS maintenance while minimizing space requirements.
Manageability
LCD graphics touch screen display
Full color text and mimic diagrams that easily display modes of operation, systems parameters and alarms.
StruxureWare Central compatible
Enables centralized management via StruxureWare Central.
Mimic Diagram
Allows instant access to the status of the UPS.
Integrated network management
Provides complete remote monitoring and control of the UPS. Enables you to monitor remote UPS’s from a web browser or industry standard Network Management System.
LED status indicators
Quickly understand unit and power status with visual indicators.
Convenience
Swappable batteries
Allows quick addition of runtime capacity or replacement of existing battery modules. Installed modules are automatically recognized by the system.
5×8 Start-up service included
Required for full coverage of factory warranty
Wheel mounted
Allows for ease of handling during installation.
Top and bottom cable entry
Allows cabling from the top and bottom without the need of additional cabinets providing footprint savings and flexibility to the installation.
Safety
Seismic compliance
These all-steel enclosures meet IBC Zone 2 seismic rating.
Internal backfeed protection
Increase system defense from power anomolies.
Total Cost of Ownership
ECOnversion mode
Operating mode that ensures ultra high efficiency while charging the batteries, conditioning the load power factor and ensuring a Class 1 output voltage regulation.
Robust operation
No power derating in kW up to 40 degrees C or 104 degrees F.
ECO Mode
Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection
High efficiency
High efficiency rates that remain stable even at lower operating power levels
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Wide input voltage range
Designed for harsh electrical environments to save battery life.
Specifications UPS Galaxy VM 160 kVA GVMSB160KHS
Output
-
Output power capacity
144.0 KWatts / 160.0 kVA
-
Max Configurable Power (Watts)
144.0 KWatts / 160.0 kVA
-
Nominal Output Voltage
400V 3PH
-
Neutral Output Current
231 A
-
Output Voltage Distortion
Less than 2%
-
Output Frequency (sync to mains)
50/60 Hz +/-1 Hz
-
Output Frequency (not synced)
50/60 Hz +/-1 Hz
-
Other Output Voltages
380, 415
-
Load Crest Factor
Unlimited
-
Topology
Double Conversion Online
-
Waveform type
Sine wave
-
Overload Operation
10 minutes @ 125% and 60 seconds @ 150%
-
Output Connections(1) Hard Wire 5-wire (3PH + N + G) (Battery Backup)(1) Hard Wire 4-wire (3PH + G) (Battery Backup)
-
Output Voltage THD
< 2% linear load and <3% non-linear load
-
Output Voltage Tolerance
+/- 1% static and +/- 3% at 100% load step
-
Bypass
Built-in Static Bypass
Input
-
Nominal Input Voltage
400V 3PH
-
Input frequency
40 – 70 Hz
-
Input Connections
Hard Wire 3-wire (3PH + G)
-
Input voltage range for main operations
320 – 456 (380V), 320 – 480 (400V), 320 – 498 (415V) V
-
Input voltage adjustable range for mains operation
250 – 600 V
-
Input Total Harmonic Distortion
Less than 3% for full load
-
Type of Input Protection Required
gL fuse
-
Maximum Short Circuit Withstand (Icw)
65.0 kAmps
-
Maximum Input Current
262.0 A
-
Input Power Factor at Full Load
1.0
Batteries & Runtime
-
Battery type
No internal battery – uses external battery system
-
Nominal Battery Voltage
480V
-
End of Discharge Maximum Battery Current
314.0 A
-
End of Discharge Battery Voltage
384
-
Efficiency
Communications & Management
-
Control panel
7″ Touch Screen Display
-
Audible Alarm
Audible and visible alarms prioritized by severity
-
Emergency Power Off (EPO)
Yes
-
Available SmartSlot™ Interface Quantity
2
Physical
-
Maximum Height
1970 , 197.0 cm
-
Maximum Width
1052 , 105.2 cm
-
Maximum Depth
854 , 85.4 cm
-
Net Weight
699.0 kg
-
Shipping weight
744.5 kg
-
Shipping Height
2156 , 215.6 cm
-
Shipping Width
1490 , 149.0 cm
-
Shipping Depth
1052 , 105.2 cm
-
Color
White
Environmental
-
Operating Environment
0 – 40 °C
-
Operating Relative Humidity
0 – 95 %
-
Operating Elevation
0-999.9 meters
-
Storage Temperature
-25 – 55 °C
-
Storage Relative Humidity
0 – 95 %
-
Storage Elevation
0-14763.6 meters
-
Audible noise at 1 meter from surface of unit
65.0 dBA
-
Online thermal dissipation
19650.0 BTU/hr
-
Protection Class
IP 20
Conformance
-
Approvals
C-tick, CE, EN/IEC 62040-1, EN/IEC 62040-2, EN/IEC 62040-3, IBC 2012 and CBC2013 to Sds=2.02g, ISTA 2B, OSHPD, UL 1778, VFI-SS-111
-
Standard warranty
1 year on-site repair or replace with factory authorized Start-Up
General
-
Bypass Connection
Built-in Static Bypass
-
Bypass Protection Device
400.0
-
Max Bypass Input Current
231.0 A