Prolink Master II Series (1P/1P) Tower
Prolink Master II Series (1P/1P) Tower Type is a single-phase UPS system that employs a true online double-conversion technology. UPS system is designed to deliver clean and high quality electrical power to fully protect critical devices such as sensitive networks, small computer centres, servers, medical equipment, telecom applications as well as industrial applications. High input power factor correction in the system improves the efficiency and reduces overall losses. UPS is equipped with 3-stage smart charging design to optimize battery performance. This feature extends the useful service life of battery and optimizes battery recharge time. Users can easily monitor and access to their UPS status from a comprehensive LCD display. The UPS systems have USB and RS-232 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser. The Master II series (1P/1P) Tower p.f 0.9 Type is available in capacities ranging from 1KVA to 3KVA. Programmable power outlet feature is implemented in the system so that during power failure, this enables users to extend battery time to critical devices by shutting down the non-critical devices. In addition, Emergency Power O (EPO) function is also available for UPS models and which is used to protect the personnel and the equipment in case of fire outbreak or other types of emergency
– TRUE DOUBLE-CONVERSION ONLINE UPS
– WIDE INPUT VOLTAGE RANGE (110-300 VAC, 55-150 VAC)
– INPUT POWER FACTOR CORRECTION 0.99
– PROGRAMMABLE POWER MANAGEMENT OUTLETS
– EMERGENCY POWER OFF FUNCTION (EPO)
– VERY HIGH SURGE IMMUNITY UP TO 7KV, 13KA, 1300J
Key Features
• True double-conversion online UPS
• Wide input voltage range (110-300 VAC)
• Input power factor correction 0.99
• Output power factor 0.9
• 50/60 Hz Frequency Converter Mode
• Programmable power management outlets
• Emergency power off function (EPO)
• ECO mode operation for energy saving
• Generator compatible
• High overload capability and enhanced short circuit protection
• SNMP/USB/RS-232 multiple communications
• 3-stage smart charging design
• Selectable output voltage: 200-240VAC
• Laser printer and ultrasound system load acceptable
SPECIFICATIONS PRO803-ES/EL 3KVA
GENERAL
UPS Type : Tower
Phase : Single phase with ground
Rating (VA) : 3000
Nominal Power (W) : 2700
Standard Model Dimension (mm) : 421 x 190 x 318 (D x W x H)
Weight (kg) : 27
Long-run Model Dimension (mm) : 421 x 190 x 318 (D x W x H)
Weight (kg) : 13.9
INPUT
Connection Type : IEC 320-C20
Nominal Voltage : 200/208/220/230/240 VAC
Voltage Range : 110-300 VAC (Based on load at 50%) 160-300 VAC (Based on load at 100%)
Frequency Range : 40 Hz ~ 70 Hz
Power Factor : ≧0.99
THDi : ≦ 5% @100~130VAC or 205-245VAC THDU < 1.6% @ input and full linear load condition with battery fully charged
OUTPUT
Connection Type : 6 x IEC 320-C13
Nominal Voltage : 200/208/220/230/240 VAC
Voltage Regulation : ±1%
Frequency Range (Synchronized Range) : 47~53 Hz or 57~63 Hz
Frequency Range (Batt. Mode) : 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
Current Crest Ratio : 3:1
Harmonic Distortion : ≦2% THD (Linear load) ≦4% THD (Non-linear load)
ALARM & INDICATORS
Battery Mode : Sounding every 4 second
Low Battery : Sounding every second
Overload : Sounding twice every second
Fault : Continuously sounding
LCD : Load level, Battery Level, AC mode, Battery mode, Bypass mode and Fault
CONNECTIVITY, CONTROL & MONITORING
Front panel : Status LED, Function keys,LCD display
Communication : Smart RS232* USB Port Emergency Power Off (EPO)
BATTERY
Standard Model Type : 12V / 9Ah
Numbers : 6
Typical Recharge Time : 4 hours recover to 90% capacity
Long-run Model Type : Depending on the capacity of external batteries
Numbers : 6
Charging Current (max) : 1A/2A/4A/6A/8A (Selectable via LCD setting)
Rear Panel 1.5KVA
1. Programmable outlets: connect to non-critical loads
2. Output receptacles: connect to mission-critical loads
3. AC input
4. Input circuit breaker
5. Network/Fax/Modem surge protection
6. Emergency power o function connector (EPO)
7. USB communication port
8. RS-232 communication port
9. Intelligent slot
10. External battery connection (Only available for L model)
11. Output terminal
12. Output circuit breaker
13. Cooling fan