APC Smart-UPS SRT 8000VA 230V (SRT8KXLI)
Includes: CD with software , Documentation CD , Installation guide , Temperature Probe , USB cable , Warranty card , Web/SNMP Management Card.
SRT8KXLI Features
APC Smart-UPS SRT 8000VA 230V
10/100 BaseT Connection
Connect the device to a network using a 10 or 100 BaseT connection
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms.
Smart-UPS On-Line Features & Benefits
Protection
Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
Cold-start capable
Provides temporary battery power when the utility power is out.
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Adaptability
Plug-and-Play external batteries
Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
Flash upgradeable firmware
Install maintenance releases of firmware remotely using FTP.
Rack/Tower convertible
Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
Serviceability
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Audible alarms
Provides notification of changing utility power and UPS power conditions
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Predicitive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.
Availability
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Scalable runtime
Allows additional run time to be quickly added as needed.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS power overload or fault.
Marketing Features
Low operating and maintenance costs with proven reliability and intelligent battery management.
Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Automatic self tests insure battery reliability and warn customers in advance of battery replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down.
Avoids costly power problems by keeping your IT equipment and data protected and available.
Network grade power conditioning protects from damaging surges and disruptive noise. The double conversion architecture provides tight voltage regulation, frequency regulation ,and zero transfer time to battery during power events.
Peace of mind that comes with full equipment compatibility and reliability of a leader
Provides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry’s most rigorous standards.
Save time with easy and convenient remote accessibility.
Network manageable via serial, USB or optional Ethernet. Includes Powerchute® Network Shutdown Software for convenient monitoring and control, safe operating system shutdown, and innovative energy management capabilities.
Manageability
Network manageable
Provides remote power management of the UPS over the network.
InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure Manager.
Serial connectivity
Provides management of the UPS via a serial port.
LED status indicators
Quickly understand unit and power status with visual indicators.
SmartSlot
Customize UPS capabilities with management cards.
Specifications apc SRT8KXLI
Form Factor |
Tower |
Daya Keluar |
8000VA / 8000W |
Voltase Masuk |
Nominal Input Voltage : 230V, 400V 3PH Input Frequency : 40 – 70 Hz (auto sensing) Input Connections : Hard Wire 3 wire (1PH+N+G) Hard Wire 5-wire (3PH + N + G) Input voltage range for main operations : 160 – 275V Input voltage adjustable range for mains operation : 100 – 275 (half load), 173 – 476 (half load)V Other Input Voltages : 220, 240, 380, 415 |
Voltase Keluar |
Output Power Capacity : 8000VA / 8000W Max Configurable Power : 8000VA / 8000W Nominal Output Voltage : 230V Output Voltage Distortion : Less than 3% Output Frequency (sync to mains) : 50/60 Hz +/- 3 Hz Other Output Voltages : 220, 240 Crest Factor : 3 : 1 Topology : Double Conversion Online Waveform Type : Sine wave Output Connections : (1) Hard Wire 3-wire (H N + G) (6) IEC 320 C13 (4) IEC 320 C19 (3) IEC Jumpers Bypass : Internal Bypass (Automatic and Manual) |
Surge Energy Rating |
Surge energy rating : 480 Joules |
Back-Up Time Half Load |
15 min (4000 Watts) Typical backup time at : 4000 Watt SRT8KXLI : 15 mins SRT8KXLI + (1)SRT192BP2 : 35 mins SRT8KXLI + (2)SRT192BP2 : 55 mins SRT8KXLI + (3)SRT192BP2 : 1 hrs 17 mins SRT8KXLI + (4)SRT192BP2 : 1 hrs 39 mins SRT8KXLI + (5)SRT192BP2 : 2 hrs 1 mins SRT8KXLI + (6)SRT192BP2 : 2 hrs 24 mins SRT8KXLI + (8)SRT192BP2 : 3 hrs 10 mins SRT8KXLI + (10)SRT192BP2 : 3 hrs 58 mins |
Back-Up Time Full Load |
5 min (8000 Watts) Typical backup time at : 8000 Watt SRT8KXLI : 5 mins SRT8KXLI + (1)SRT192BP2 : 15 mins SRT8KXLI + (2)SRT192BP2 : 25 mins SRT8KXLI + (3)SRT192BP2 : 35 mins SRT8KXLI + (4)SRT192BP2 : 45 mins SRT8KXLI + (5)SRT192BP2 : 56 mins SRT8KXLI + (6)SRT192BP2 : 1 hrs 6 mins SRT8KXLI + (8)SRT192BP2 : 1 hrs 28 mins SRT8KXLI + (10)SRT192BP2 : 1 hrs 51 mins |
Antarmuka / Interface |
Contact Closure, RJ-45 10/100 Base-T, RJ-45 Serial, Smart-Slot, USB Available SmartSlot™ Interface Quantity : 1 |
Baterai |
Battery Type : Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof Typical recharge time : 1.50 hour(s) Replacement Battery : APCRBC140 Extended Run Options : APC Smart-UPS SRT 8000VA 230V RBC™ Quantity : 2 |
Dimensi |
263 x 432 x 715 mm (WxHxD) (max) |
Berat |
111.82 kg |
Kelengkapan Paket |
CD with software Documentation CD Temperature Probe Warranty card Web/SNMP Management Card USB cable Installation guide |
Lain-lain |
Material produk ini termasuk dalam pengawasan regulasi keselamatan, pengiriman lintas pulau mungkin terkena tambahan biaya atau keterlambatan pengiriman. |
Kata Kunci Terkait :
harga apc SRT8KXLI, jual apc SRT8KXLI, spesifikasi apc SRT8KXLI, beli apc SRT8KXLI